    Ask Lasest Price
    Brand Name : GINRI
    Model Number : DVM-A
    Certification : CE CCC
    Payment Terms : L/C, T/T, Western Union,Paypal
    Supply Ability : 20000Pcs per month
    Delivery Time : 1-30 days upon order quantity
    • Product Details
    • Company Profile

    48 Volt DC Voltage Monitoring Relay Electric control system CE / CCC Cetificayion

    48 Volt DC Voltage Monitoring Relay Electric control system CE / CCC Cetificayion


    Overvoltage protection: When the fault voltage exceeds the protection setting value, a trip command or overvoltage signal is issued.
    Low-voltage protection: When the fault voltage is lower than the protection setting value, a trip command or low-voltage signal is issued.
    Overvoltage protection
    Overvoltage refers to any voltage whose peak value is greater than the corresponding peak value of the maximum steady state voltage under normal operation. In engineering, it refers to any dangerous voltage that may cause damage to the equipment. Therefore, in the project, some overvoltages that are larger than the normal operating voltage but are not enough to endanger the normal operation of the equipment are excluded. Overvoltage includes:
    (1) Transient overvoltage, duration of milliseconds or less, is the main protection target for lightning arresters.
    (2) Transient overvoltage or short-term overvoltage, the duration is relatively long, generally between 0.1s and 1s.
    The sources of transient overvoltages are: lightning strikes, switching operations, electrostatic discharges, and nuclear explosions. At the communications station, lightning overvoltages or lightning overvoltages are predominant.
    Transient overvoltages mainly include: over-voltage transfer, zero-off over-voltage, over-voltage resonance over-voltage and over-voltage caused by the drift of the neutral line. In addition, capacitive effects, unbalanced ground faults, and sudden load dumps on no-load lines can also create dangerous overvoltages.


    ♦ Features

    -- DC circuit monitoring of over and undervoltage

    -- Adjustable over- and undervoltage threshold
    -- Adjustable trip delay time

    -- Powered by the measuring circuit

    -- 1 C/O contact

    -- 2 LEDs for status indication


    Protective Functions

    -- Overvoltage

    -- Undervoltage


    ♦ Typical Applications

    • DC cabinet • Batteries

    • Electric control system


    ♦ Approvals

    CE CCC


    ♦ Technical data


    TypeDVM-A
    MeasuringDC circuit
    Rated voltageDC12V,DC24V,DC36V,DC48V
    Monitoring functionsovervoltage,undervoltage
    Voltage setting range
    Rated voltageUndervoltageOvervoltage
    DC12V10-14V13-17V
    DC24V20-28V26-34V
    DC36V30-42V39-51V
    DC48V40-56V52-68V
    Trip delay time1-15s adjustabel
    IndicatorsNormal,Trip
    Output contacts2 C/O
    Contact capacity5A,250VAC
    Dimensions(H*W*D)50*40*57.5mm
    Mountingplug-in