    Brand Name : GINRI
    Model Number : SVR1000
    Certification : CE
    Payment Terms : L/C, T/T, Western Union,Paypal
    Supply Ability : 20000Pcs per Month
    Delivery Time : 5-8 working days
    • Product Details
    • Company Profile

    AD220 Single Phase Voltage Monitoring Relay Over / Under Voltage Protector 220V 380V


    GINRI SVR1000 Single Phase Voltage Relay Adjustable Over Under Voltage Protection Monitor Relay with LCD display

    The Features of SVR10000
    -- Powered by the measuring circuit
    -- Built-in LCD and keypad afford a precise,digital setting
    -- Compact modular 43mm housing
    -- Adjustable over- and undervoltage threshold
    -- Independent adjustable delay time for overvoltage, undervoltage
    -- 1 CO & 1NC contacts
    -- Fault recording with last 3 faults

    ♦ Protective Functions
    -- Overvoltage
    -- Undervoltage

    ♦ Typical Applications
    • Pumps • Fans
    • Blowers • Motors
    • Compressors

    ♦ Approvals
    • CE • CCC

    ♦ Technical data

    ModelSVR1000/D12SVR1000/AD48SVR1000/AD220
    Measuring circuitA1+,A2-
    Rated voltageDC 12VAC/DC 24~48V,50/60Hz

    AC/DC
    110~240V,50/60Hz

    Monitoring functionsovervolatege, undervoltage
    Overvoltage setting range

    DC
    9.0~18.0V adjustable

    AC/DC 20.0~80.0V adjustable

    AC/DC
    50.0~300V adjustable

    Undervoltage setting range

    DC
    9.0~18.0V adjustable

    AC/DC 20.0~80.0V adjustable

    AC/DC
    50.0~300V adjustable

    Voltage hysteresis0.1~6.0V adjustable0.1~30.0V adjustable1.0~90.0V adjustable

    Delay time for overvoltage
    and undervoltage

    0.1-999s adjustable
    Reset modeManual/ Automatic/Automatic with power-on delay
    Delay time for reset0.1-999s adjustable
    IndicatorsLCD indicating voltage,operationand fault status
    Output contacts1 CO & 1NC
    Contact capacity6A ,250VAC
    Dimensions (H x W x D)80×43×54mm
    MountingDIN rail































    12


    The reason of used the over under voltage relay

    Take the electric equipment on the line as an example. If the electric energy can't keep up, the voltage will drop very much. According to the formula: P=U*I, U becomes smaller, I will become larger, and U is smaller than the current I on the line. It will be bigger.
    For example, when U starts, it is U1. At this time, I=I1=P/U1. If the power can't keep up at this time, because the power consumption P needs to be used, the U drops to 0.5U1. Current:
    I=P/U=P/(0.5U1)=2*(P/U1)=2I1
    In other words, if the voltage drops by half, the current will double.
    In this case, the problem comes. According to the well-known Joule law: heat quantity Q=I*R*T
    The resistance value R of any device on the line is certain. If the previous line heat is Q1=I1*R*T, the voltage U changes to 0.5U1, the current I is 2I1, and the line heats up Q2= I*R* T = (2I1) * R * T = 4 * I1 * R * T = 4Q1, that is, if the voltage drops by half, the heat generated per unit time will become four times the previous one.
    It can be seen that the change of the heat per unit time of the device on the line is inversely proportional to the square of the change of the line voltage. Therefore, the more the voltage drops, the greater the heat generated by the device on the line, and the heat accumulation of the device on the line exceeds the thermal diffusion. The speed of the device will become higher and higher, which may cause accidents such as fire.
    Therefore, it is necessary to set a threshold voltage for the line. When the line voltage drops to this threshold voltage, the line is cut off by a relay protection device or the like, thereby ensuring that the device on the entire circuit does not burn out. This is called undervoltage protection.

    Quality AD220 Single Phase Voltage Monitoring Relay Over / Under Voltage Protector 220V 380V for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Wenzhou Ginri Power Automation Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)