    Brand Name : Ginri
    Model Number : DVM-A
    Certification : ce
    Payment Terms : L/C, D/P, T/T, Western Union
    Supply Ability : 1000PCS per month
    Delivery Time : 2-5days
    • Product Details
    • Company Profile

    Time Delay DC Voltage Monitoring Relay Plug - In Module With DIN Socket

    Time Delay DC Overvoltage Protection Relay Plug - In Module With DIN Socket


    ■Features:
    ● Overvoltage protection ● Undervoltage protection ● 8PFA base mounting


    ■Application:
    Products are widely used: variable frequency power supply, UPS power supply and various instrumentation
    Table DC power supply overvoltage and undervoltage protection.


    ■ Structural features:
    1. The protector is installed on the base of 8PFA. The base is equipped with two M4 screw holes, which can be installed independently or using HT35 rails.
    2. Indicator light: 2 indicator lights, divided into power indication and normal operation indication.
    3. Outer dimensions: 50mm x 40mm x 57.5mm.


    Overvoltage protection, also known as overvoltage protection, is a type of protection that disconnects the power supply or reduces the voltage of the controlled device when the protected line voltage exceeds a predetermined maximum value. Overvoltage protection is usually configured with varistors. When the transient high voltage generated by the circuit is applied to both ends of the varistor, the resistance of the varistor becomes infinitely small, which makes the varistor conduct and passes the large current generated by the circuit to earth through the ground wire, thereby protecting the power supply device from being affected. High voltage damage.

    It should be noted that overvoltage protection will start immediately and overcurrent protection will have a delay of about one second. This is because if the power supply works normally, such as a sudden short circuit in the load of the power supply, the instantaneous current output by the power supply is several times or several times the rated current value. It can be considered as a current surge, far exceeding the overcurrent protection. Value, but this time does not want overcurrent protection to work. But after the short circuit is released, the voltage automatically returns to normal. Therefore, when designing over-current protection, current surges during sudden short-circuiting must be avoided, and only the duration of the output over-current should be considered to start the over-current protection.

    • Plug-in module with DIN socket
    • DC circuit monitoring of over-and undervoltage
    • Adjustable over and undervoltage threshold
    • Adjustable trip delay time
    • Powered by the measuring circuit
    • 2C/O contacts
    • 2 LEDs for status indication

    Protective Functions

    • DC voltage
    • DC undervoltage

    Applications

    • DC cabinet
    • Battery
    • Electric control system

    ModelDVM-A
    Input circuit=Measuring circuitDC supply
    Rated voltageDC12V,DC24V,DC36V,DC48V
    Monitoring functionsovervoltage,undervoltage
    Voltage setting range
    Rated volatgeundervoltageOvervoltage
    DC12V10-14V13-17V
    DC24V20-28V26-34V
    DC36V30-42V39-51V
    DC48V40-56V52-68V

    Tripping delay time1-15s adjustable
    Voltage hysteresis3-5% fixed
    Reset delay time100ms
    Indicatorsnormal,trip
    Output contacts2C/O
    Contact capacity5A,250VAC/30VDC(resistive load)
    Degree of protectionIP20
    Working conditions-25%~65℃,≤85%,non-condensing
    Mechanical durability1000000cycles
    Dielectric strength>2KVA 1min
    Weight160g
    Dimension50x40x57.5mm
    Applicable socketPF085A &SH-3
    MountingDin Rail